Metrological characteristics | |
---|---|
Measured physical value | tilt angle for X and Y axes |
Measuring range for X and Y axes | from -15° to +15° |
Tolerance limits of intrinsic absolute error of tilt measurements |
±(0,045°+0,045×φ) where φ – tilt angle measured value |
Inherent “drift” of zero in 100 hours, related to tilt measurement range in normal conditions, maximum | ±0,045° |
Inherent “drift” of zero for 1 year, related to tilt measurement range in normal conditions, maximum | ±0,07° |
Tolerance limits of complementary error caused by 10°C temperature change | ±0,05° |
Real time operation control |
synchronization quality data quality |
Measurement reliability control | sensing element integrity check |
Specifications | |
Data refresh rate | 1 Hz |
Sensor type | integrated sensing element |
Data transfer interface | CAN 2.0 |
Exchange speed | 100, 300, 1000 kb/sec |
Interface inputs overvoltage protection (current 1 A) | 19 V |
Interface inputs impulse protection (350 W, 8/20 ms) | 28 V |
Operational specifications | |
Dimensions | 98×105×28 mm |
Weight | 315 g |
Device power | from 9 to 24 V |
Consumed power | 0,5 W |
Operational temperature range | from -40 to +80 °C |
Product version |
Standard (protection index IP65) Explosion-proof* (explosion protection, type 0ExiaIICT6 X (IP67)) OEM (compound coating) |
Electromagnetic compatibility EMC | |
IEC 61000-4-2, ESD | contact 8 kV, air 15 kV |
IEC 61000-4-4, EFT | power 4 kV, signal 2 kV |
IEC 61000-4-5, Surge | 4000 V |