METROLOGICAL PERFORMANCE | |
---|---|
Measured physical value | tilt angle for 2 axes X and Y |
Measuring range for X and Y axes | -15° to +15° |
Tolerance limits of intrinsic absolute error of tilt measurements |
±(0.045°+0.045×φ) where φ – tilt angle measured value |
Inherent “drift” of zero in 100 hours, related to tilt measurement range in normal conditions, maximum | ±0.045° |
Tolerance limits of complementary error caused by 10°C temperature change | ±0.05° |
SPECIFICATIONS | |
Rate of data update | 1 Hz |
Transducer type | integrated sensing element |
Data interface | RS-485 |
Exchange rate | 4,800, 9,600, 14,400, 19,200, 38,400, 57,600, 115,200 bit/s |
Parity check | 0 — no check, 1 — check (odd parity, ODD)) |
Exchange protocol | Modbus RTU |
PERFORMANCE PARAMETERS | |
Dimensions | 98×105×28 mm |
Weight | 315 g |
Device power | 9 to 24 V |
Power consumption | 0.3 W |
Polarity reverse protection | available |
Operating temperatures | -40 to +80 °C |
Version |
Standard (protection index IP65) Explosion-proof* (explosion protection, type 0ExiaIICT6 X) OEM (compound-coated plate) |
ELECTROMAGNETIC COMPATIBILITY EMC | |
IEC 61000-4-2, ESD | contact 8 kV, air 15 kV |
IEC 61000-4-4, EFT | power 4 kV, signal 2 kV |
IEC 61000-4-5, Surge | 4,000 V |
*Cost is calculated on individual basis