Controlled parameter | Acceleration | Velocity | Ground water level | Temperature | Humidity | Atmospheric pressure | Temperature | Atmospheric pressure | Hydrodynamic noise |
Module/ digital sensor type | ZET 7152-N | ZET 7156 | ZET 7112-I |
ZET 7120 ZET 7020 |
ZET 7123 ZET 7023 |
ZET 7112-A | ВС 314-М | ||
Measuring unit | m/s2 | µm/m | mm WG | °С | % | kPa | °С | kPa | dB |
Measurement range | -20…20 | 0,1…250 | 10…5000 | -50…+120 | 0…100 | 50…115 | -40…+60 | 80…120 | 60…180 |
Minimal registered value | 0,01 | 0,1 | 0,1 | 0,1 | 1 | 0,5 | 0,2 | 0,1 | 1 |
ALARM: bottom threshold level | 0,05 | 2 | 5 | 5 | 10 | 5 | 2 | 10 | 10 |